Building Intelligence
|
Multipoint Sensor (MPS)
| |
Provides a method to obtain moisture content readings over a large contiguous area using a single WiDAQ input. |
Overview
General Description
The MPS returns a moisture content value representing the total parallel moisture content of all probed locations. Due to the nature of moisture content readings, wet readings overshadow milder conditions allowing the operator to differentiate between dry and wet conditions.
Sensor data from the MPS is transmitted to the Building Intelligence Gateway where temperature compensation and wood species correction factors are applied.
Features
- Standard model covers 8 contact point locations over a 25 foot span
- Built in temperature sensor allows for temperature compensation
- Terminated on standard audio jacks for easy compatibility with SMT WiDAQs
- Compact, low profile, very flexible design allows for easy deployment
- Temperature data is transmitted and recorded along with Moisture Content Data
- Sensor can be reused on various restoration sites
Specs
|
Electrical Characteristics |
|
|
Operating Voltage |
2V to 12VDC |
|
Resistance Measurement Range |
100Ω to 1GΩ |
|
Thermistor Measurement Range |
-40°C to 125°C |
|
Thermistor part number |
Cantherm MF52104F3950 |
|
NTC Thermistor Beta Value |
3950 |
|
Environmental |
|
|
Operating Temperature |
-40° to 50°C / -40° to 122°F |
|
Application Temperature |
5° to 50°C / 41° to 122°F |
|
Storage Temperature |
-40° to 50°C / -40° to 122°F |
|
Storage Humidity |
30% to 70% RH |
|
Physical – MPS-001-025 |
|
|
Length |
7.62m (25 feet) |
|
Termination |
3.5mm Audio Jack |
|
Probe locations |
8 locations spaced 61 cm (24 inches) apart |
Connectivity
|
MPS |
Audio |
Function |
|
A |
Red |
Moisture |
|
B |
Black |
Thermistor |
|
C |
Yellow |
Thermistor (Com) |
|
D |
Green |
Moisture (Com) |

Applications

MPS Sensor installed along base plate on basement floor.
Stainless Steel ¾” screws are driven into the MPS at pre-defined locations.
Any number of probes sets (screw pairs) may be deployed depending on the desired area to monitor and the MPS length.
For the 8 contact point model any number between 1 and 8 contact points may be used.